CS475, CS476 & CS477 Radar Water Level Sensor User Manual Issued 8.4.13 Copyright © 2009-2013 Cam
iv
1 CS475, CS476, and CS477 Radar Water Level Sensor 1. Introduction The CS475, CS476, and CS477 are radar-ranging sensors that monitor the water level
CS475, CS476, and CS477 Radar Water Level Sensor 2 3. Initial Inspection When unpacking the equipment, do the following: • Unpack the unit in a clean
User Manual 3 Table 4-2. Radiation Beam Spread for CS475 (10° Beam Angle) Distance in Metres Diameter of Footprint in Metres 1 0.18 5 0.87 10 1.76
CS475, CS476, and CS477 Radar Water Level Sensor 4 CS475 CS476/CS477 12 Figure 4-1. Polarization markings (see Table 4-4 for label descriptions) Ta
User Manual 5 Table 4-5. Example of a Start False Echo Learn Command Initial Command Response 0XSFEL+2.500! Where (from left to right), 0—sensor’s
CS475, CS476, and CS477 Radar Water Level Sensor 6 4.4 Step 4 — Use SCWin Short Cut to Program Datalogger and Generate Wiring Diagram 1. Open Short
User Manual 7 3. Under Generic Measurements, select SDI-12 Sensor then click the right arrow to add it to the list of sensors to be measured. 4. A
CS475, CS476, and CS477 Radar Water Level Sensor 8 5. Choose the outputs and then select Finish. 6. Wire according to the wiring diagram generated
User Manual 9 Three sensor models are available that differ in their measurement range and accuracy. The CS475 can measure distances up to 65 feet wi
CS475, CS476, and CS477 Radar Water Level Sensor 10 Figure 5-2. Components and hardware (see Table 5-1 for description of labels) Table 5-1. Descri
User Manual 11 • Low maintenance—no moving parts significantly reduces maintenance cost and time • Low power consumption • Rugged enough for hars
CS475, CS476, and CS477 Radar Water Level Sensor 12 6.1 Radar Unit Frequency: ~26 GHz Electromagnetic Compatibility: Emission to EN 61326; Elect
User Manual 13 6.3 Physical See Figure 6-2 and Figure 6-3 for dimensions. Rating: NEMA 4x Housing Material: Aluminium, coated IP66/68 Horn Materia
CS475, CS476, and CS477 Radar Water Level Sensor 14 Figure 6-3. CS476/CS477 dimensions 585 mm (23 in) 430 mm(16.9 in) 86 mm (3.4 in) 86 mm(3.4
User Manual 15 7. Installation Before installing the radar sensor, you must consider all the suggested guidelines for site and maintenance issues. Do
CS475, CS476, and CS477 Radar Water Level Sensor 16 7.2 Sensor Alignment 7.2.1 Vertical Use a user-supplied bubble level or the #25619 bubble level to
User Manual 17 Table 7-1. Wiring Diagram Colour Description CR800, CR850, CR1000, CR3000, CR10(X), CR510, CR500 CR23X CR5000 CR20
CS475, CS476, and CS477 Radar Water Level Sensor 18 The values returned from the SDI12Recorder() instruction are different depending on the SDI-12 mea
User Manual 19 Minimum(1,Distance,FP2,0,0) Average(1,Distance,FP2,False) StdDev(1,Distance,FP2,False) Maximum(1,Stage,FP2,0,0) Minimum(1,Stage,
Guarantee This equipment is guaranteed against defects in materials and workmanship. This guarantee applies for twelve months from date of delivery.
CS475, CS476, and CS477 Radar Water Level Sensor 20 7.5.2.1 Example Program Below is a portion of a CR10X program that measures the radar sensor. The
User Manual 21 6. Send the Start Verification command followed by the Get Data command (see Section 8.1.4, Cyclic Redundancy Check). 7. Use the Get
CS475, CS476, and CS477 Radar Water Level Sensor 22 8.1.2 Check Unit Response The Acknowledge Active command is used to check the presence of the sens
User Manual 23 The verification values that will be returned are: • CRC check (error check)—values are 0 (OK) or 1 (failed) • SDI-12 Radar firmware
CS475, CS476, and CS477 Radar Water Level Sensor 24 8.2 Diagnostics and Repair The radar sensor is extremely reliable, but problems can occur during
User Manual 25 The electronics module is replaced by doing the following steps (see Figure 8-1 and Table 8-5): 1. Unscrew the housing cap (cap is not
CS475, CS476, and CS477 Radar Water Level Sensor 26 123345 Figure 8-1. Changing the electronics (see Table 8-5 for label descriptions) Table 8-5. De
A-1 Appendix A. Replacing the Cable The sensor is fitted with a cable for connection to the datalogger. The following procedure is for replacing th
Appendix A. Replacing the Cable A-2 123(A)(C)456789101112(D)13(B)1415161718 Figure A-1. Connecting the instrument housing (see Table A-1 for descrip
B-1 Appendix B. SDI-12 Commands/ Changing Settings The SDI-12 commands are entered using the #25616, Adjustment/Display Module, or the terminal emul
Appendix B. SDI-12 Commands/Changing Settings B-2 Table B-1. SDI-12 Commands Function SDI-12 Command Address Query ?! Send Identification aI! Ack
Appendix B. SDI-12 Commands/Changing Settings B-3 microwave pulses. Any echo occurring 0.5 m (1.6 ft) short of the distance you entered will be cons
Appendix B. SDI-12 Commands/Changing Settings B-4 Table B-3. Example of Setting Address Initial Command Response 0A1! Where 0 is the original ad
Appendix B. SDI-12 Commands/Changing Settings B-5 Conditions) command. Table B-5 shows an example of the command and response for changing this sett
Appendix B. SDI-12 Commands/Changing Settings B-6 Table B-6. Example for Setting Power Operation Mode Initial Command Response 0XSPOM+2! Where, 0
C-1 Appendix C. FCC/IC Equipment Authorization (USA/Canada only) The CS475, CS476, and CS477 are FCC compliant (FCC IC # M01PULS616263). Modificati
Appendix C. FCC/IC Equipment Authorization (USA/Canada only) C-2
CAMPBELL SCIENTIFIC COMPANIES Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel
PLEASE READ FIRST About this manual Please note that this manual was originally produced by Campbell Scientific Inc. primarily for the North American
i Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to specific sec
ii 8. Diagnostics, Repair, and Maintenance ... 20 8.1 Testing Procedure .....
iii 7-2. SDI-12 Command Codes .................. 18 8-1. Example of Start Measurement Command ...
Kommentare zu diesen Handbüchern