MicroMet Manual Pg. 23
Installing the new CR10X canister
! Examine the replacement CR10X canister. Notice that it has two connector plugs
which must engage two connector receptacles on the wiring panel. Notice also that
the wide connector plug must be up in relation to the mounting bracket.
! Slide the new canister from right to left into the wiring panel.
! Carefully, but firmly seat the canister’s plugs into the wiring panel’s receptacles.
Some rocking and pushing motion will facilitate this.
! Insert the tabs of the end cap into the mounting bracket at the right end of the newly
installed canister. The thumbscrew tab will project toward the wiring panel when
inserted correctly.
! Insert the thumbscrew tab into the wiring panel. The thumbscrew tab slides into the
wiring panel end such that the thumbscrew engages the thumbscrew slot in wiring
panel.
! Make sure that the rubber bumpers on the end cap project into the recessed end of
the canister.
! Tighten the thumbscrew while maintaining moderate pressure toward the canister on
the end cap.
! Reinstall the Power In connector and the CSIO connector.
Prior to closing up the wall mounted enclosure, double check that both the Power In
and the CSIO connectors are properly installed.