Met One 034B Windset
The CR10X, CR23X, and dataloggers programmed with CRBasic can also
measure wind speed on a control port. With this option the black wire is
connected to the 5 V terminal.
1
2
6
3
4
5
CONNECTOR PIN-OUT
PIN 1 - AZIMUTH SIGNAL
PIN 2 - AZIMUTH REFERENCE
PIN 3 - AZIMUTH EXCITATION
PIN 4 - PULSE OUT
PIN 5 - PULSE REFERENCE
PIN 6 - SHIELD
034B-L Windsets purchased directly from Met One Instruments
have a different configuration on the 6 pin connector. In
addition, they do not have the 10 kΩ resistance on the excitation
line. The wiring diagram and the multiplier and offset, for wind
direction, are different than the examples in this document.
NOTE
5. Programming
This section is for users who write their own programs. A datalogger program
to measure this sensor can be created using Campbell Scientifics’ Short Cut
Program Builder software. You do not need to read this section to use Short
Cut.
5.1 Wind Speed
Wind speed is measured with the Pulse Count instruction, using the Switch
Closure configuration and set to output frequency in Hertz (see Section 5.4 for
examples).
The expression for wind speed (U) is:
U = MX + B
where
M = multiplier
X = number of pulses per second (Hertz)
B = offset
Table 5-1 lists the multipliers (M) and offsets (Off) to obtain meters/second or
miles/hour when the Pulse Count instruction is configured to output the result
in Hz.
5