Met One 034B Windset
10: Set Active Storage Area (P80)
1: 1 Final Storage Area 1
2: 101 Array ID
11: Real Time (P77)
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
12: Wind Vector (P69)
1: 1 Reps
2: 0 Samples per Sub-Interval
3: 0 S, theta(1), sigma(theta(1)) with polar sensor
4: 3 Wind Speed/East Loc [ WS_ms ]
5: 4 Wind Direction/North Loc [ WindDir ]
5.5 Long Lead Lengths
When sensor lead length exceeds 100 feet, the settling time allowed for the
measurement of the vane should be increased to 20 milliseconds.
For dataloggers programmed with CRBasic, increase the “Settling Time”
parameter of the CRBasic instruction to 20 milliseconds (20,000
microseconds).
Dataloggers programmed with Edlog should use Instruction 4 – Excite-Delay
(P4), rather than Instruction 5 – AC Half Bridge (P5). Enter a 2 in the Delay
parameter for a 20 millisecond delay.
With a CR510 or CR10(X), use a 2500 mV excitation and the 2500 mV
measurement range. With a 21X, CR7, or CR23X, use a 5000 mV excitation
and the 5000 mV measurement range.
The 60 Hz rejection option can not be used with the DC
Half Bridge instruction, when the delay is not zero. Do not
use long lead lengths in electrically noisy environments.
CAUTION
TABLE 5-4. Multiplier and Offset for Wind Direction when
using Lead Lengths Greater than 100 Feet
Units
Datalogger
Type
Instruction
Number
Multiplier
Offset
degrees CR10(X)
CR510
4 0.288 0
degrees CR23X
CR7, 21X
4 0.144 0
9