
AIRMAR WeatherStation 150WX Weather Sensor
RM72004,0000171 -19-07MAY13-1/1
RM72004,000017D -19-07MAY13-1/1
Theory of Operation
The AIRMAR WeatherStation 150WX weather sensor
provides air temperature, relative humidity, wind speed,
and wind direction. Air temperature, relative humidity,
and wind speed are used to calculate evapotranspiration
(ET), a critical measurement in irrigation planning and
scheduling.
A—Weather Sensor
B—Sensor Extension Piece
C—Wiring Harness with 8-Pin
Connector
PC16619 —UN—25FEB13
Specifications
Measurements
•
Measurement Time: 10 ms
•
Power: 2.5 VDC @ 2 mA, to 5 VDC @ 7 mA
•
Output: 320–1000 mV @ 3 V excitation
•
Operating Temperature Range: -40–55 °C (-40–131 °F)
•
Air Temperature Range: -40–55 °C (-40–131 °F)
•
Air Temperature Resolution: 0.1 °C (0.212 °F)
•
Air Temperature Accuracy: ±1 °C (±1.8 °F), wind greater
than 2 m/s (4.6 mph)
•
Relative Humidity Range: 10–95% RH
•
Relative Humidity Accuracy: ±4% RH
•
Wind Speed Range: 0–40 m/s (0–92 mph)
•
Wind Speed Accuracy, Low Wind Speed: 0–5 m/s
(0–11.5 mph), RMS error of 0.5 m/s (1.1 mph) + 10%
of reading
•
Wind Speed Accuracy, High Wind Speed: 5–70 m/s
(11.5–156 mph), RMS error of 1 m/s (2.3 mph) or 5%
RMS, whichever is greater
•
Wind Direction Range: 0° to 360°
•
Wind Direction Resolution: ±0.1°
•
Wind Direction Accuracy, Low Wind Speed: 2–5 m/s
(4.6–11.5 mph), 5° RMS, typical
•
Wind Direction Accuracy, High Wind Speed: Greater
than 5 m/s (greater than 11.5 mph), 2° RMS, typical
NOTE: When the wind speed is less than 2 m/s (4.6
mph) and/or air temperature is below 0 °C (32
°F), wind, temperature, and relative humidity
readings will be less accurate.
RMS error (root-mean-square error) is a measure
of the differences between values predicted by a
model and the values actually observed.
Dimensions, Sensor Body
•
Diameter, Top: 72 mm (2.83 in.)
•
Diameter, Nut Assembly, Connection With Sensor
Body: 45 mm (1.77 in.)
•
Length, Total: 131 mm (5.16 in.)
•
Length, Sensor Body: 90 mm (3.54 in.)
Dimensions, Cable
•
Length: 6 m (20 ft.)
•
Connector Type: Molex MX150
50-1
052813
PN=49
Kommentare zu diesen Handbüchern