Specifications
Continued on next page RM72004,000019C -19-07MAY13-1/2
Field Connect Gateway
Electrical
•
Input Voltage—Range, switched and unswitched power,
9–32 VDC
•
Fuse Recommendations—Protect device with a 5 A
fuse, maximum
Battery
•
Nominal Voltage—12 VDC
•
Rated Capacity—12.0 Ah/0.60 A (20 hr., 1.8 V/cell, at
25 °C (77 °F))
LED Display
A—CELL
B—GPS
C—SAT
D—BATT
E—DIG 1–4
F— FAULT
G—ALG 1–4
H—FRQ 1, 2
I— USB (Multi-colored LED:
Green, Red, Blue)
J— SER 1, 2
K—SMP 1, 2
PC16590 —UN—07FEB13
LED Display
LED
STATE DESCRIPTION
Solid Connection established
Blinking
Attempting connection/unable to connect
CELL (A)
Off
Device not enabled
Solid Connection established
Blinking
Attempting connection/unable to connect
GPS (B)
Off
Device not enabled
Solid Connection established
Blinking
Attempting connection/unable to connect
SAT (C)
Off
Device not enabled
Solid
Battery connected
Blinking
Critical power state
BATT (D)
Off
Unit not powered
Solid
Device present
Blinking
Channel enabled; no device detected
DIG 1 (E)
Off Channel disabled
Solid
Device present
Blinking
Channel enabled; no device detected
DIG 2 (E)
Off Channel disabled
Solid
Device present
Blinking
Channel enabled; no device detected
DIG 3 (E)
Off Channel disabled
Solid
Device present
Blinking
Channel enabled; no device detected
DIG 4 (E)
Off Channel disabled
Solid N / A
Blinking Urgent Fault
FAULT (F)
Off
No Fault Active
Solid
Device present
Blinking
Channel enabled; no device detected
ALG 1 (G)
Off Channel disabled
35-1
052813
PN=44