Analog Inputs
Eight differential (16 single-ended) channels mea-
sure voltage levels. Resolution on the most sensitive
range is 0.67 µV.
Pulse Counters
Two pulse channels can count pulses from high level
(5 V square wave), switch closure, or low level AC signals.
Switched Voltage Excitations
ree outputs provide precision excitation voltages for
resistive bridge measurements.
Digital I/O Ports
Eight ports are provided for frequency measurements,
digital control, and triggering.  ree of these ports can
also be used to measure SDM devices.  e I/O ports
can be paired as transmit and receive. Each pair has 0
to 5 V UART hardware that allows serial communica-
tions with serial sensors and devices. An RS232-to-
logic level converter may be required in some cases.
CS I/O Port
AC-powered PCs and many communication peripherals
connect with the CR1000 via this port. Connection to
an AC-powered PC requires either an SC32B or SC-USB
interface.  ese interfaces isolate the PC’s electrical
system from the datalogger, thereby protecting against
ground loops, normal static discharge, and noise.
RS-232 Port
This non-isolated port is for connecting a battery-
powered laptop, serial sensor, or RS-232 modem.
Because of ground loop potential on some measure-
ments (e.g., low level single-ended measurements),
AC-powered PCs should use the CS I/O port instead of
the RS-232 port (see above).
Peripheral Port
One 40-pin port interfaces with the NL115 Ethernet
Interface & CompactFlash Module, the NL120 Ether-
net Interface, or the CFM100 CompactFlash® Module.
Switched 12 Volt
is terminal provides unregulated 12 V that can be
switched on and o under program control.
Storage Capacity
e CR1000 has 2 MB of  ash memory for the Operat-
ing System, and 4 MB of battery-backed SRAM for CPU
usage, program storage, and data storage. Data is stored
in a table format.  e storage capacity of the CR1000
can be increased by using a CompactFlash card.
Communication Protocols
e CR1000 supports the PB, Modbus, DNP3,
TCP/IP, FTP, and SMTP communication protocols.
With the PB protocol, networks have the distrib-
uted routing intelligence to continually evaluate links.
Continually evaluating links optimizes delivery times
and, in the case of delivery failure, allows automatic
switch over to a con gured backup route.
e Modbus RTU protocol supports both  oating
point and long formats.  e datalogger can act as a
slave and/or master.
e DNP3 protocol supports only long data formats.
e dataloggers are level 2 slave compliant, with some
of the operations found in a level 3 implementation.
e TCP/IP, FTP, and SMTP protocols provide TCP/IP
functionality when the CR1000 is used in conjunction
with an NL115, NL120, or third party serial IP device.
Refer to the CR1000 manual for more information.
Power Supplies
Any 12 Vdc source can power the CR1000; a PS100 or
BPALK is typically used.  e PS100 provides a 7-Ahr
sealed rechargeable battery that should be connected
to a charging source (either a wall charger or solar
panel).  e BPALK consists of eight non-rechargeable
D-cell alkaline batteries with a 7.5-Ahr rating at 20°C.
Also available are the BP12 and BP24 battery packs,
which provide nominal ratings of 12 and 24 Ahrs,
respectively.  ese batteries should be connected to a
regulated charging source (e.g., a CH100 connected to
a unregulated solar panel or wall charger).
Enclosure/Stack Bracket
A CR1000 housed in a weather-resistant enclosure
can collect data under extremely harsh conditions.
The 17565 Stack Bracket allows a small peripheral
to be placed under the mounting bracket, thus
conserving space. With the bracket, the CR1000
can be attached in a “horizontal” orientation in
an ENC10/12 enclosure (i.e., the long axis of the
CR1000 spanning the short axis of the enclosure).
Above shows a side view of the stack bracket. The
CR1000 is fastened to the bracket via Velcro straps.