Seitenansicht 4
Channel Expansion
4-Channel Low Level AC Module
e LLAC4 is a small peripheral device that allows
customers to increase the number of available low-
level ac inputs by using control ports.  is module is
o en used to measure up to four anemometers, and is
especially useful for wind pro ling applications.
Synchronous Devices for Measurement (SDMs)
SDMs are addressable peripherals that expand the data-
logger’s measurement and control capabilities. For
example, SDMs are available to add control ports, analog
outputs, pulse count channels, interval timers, or even
a CANbus interface to the system. Multiple SDMs, in
any combination, can be connected to one datalogger.
Multiplexers
Multiplexers increase the number of sensors that can
be measured by a CR1000 by sequentially connecting
each sensor to the datalogger. Several multiplexers can
be controlled by a single CR1000.
Software
Starter So ware
Our easy-to-use starter so ware is intended for  rst
time users or applications that dont require sophisti-
cated communications or datalogger program editing.
SCWin Short Cut generates straight-forward CR1000
programs in four easy steps. PC200W allows custom-
ers to transfer a program to, or retrieve data from a
CR1000 via a direct communications link.
At www.campbellsci.com/downloads you can down-
load starter so ware at no charge. Our Resource CD
also provides this so ware as well as PDF versions of
our brochures and manuals.
Datalogger Support So ware
Our datalogger support so ware packages provide
more capabilities than our starter so ware.  ese
so ware packages contains program editing, commu-
nications, and display tools that can support an entire
datalogger network.
PC400, our mid-level so ware, supports a variety of
telemetry options, manual data collection, and data
display. For programming, it includes both Short Cut and
the CRBasic program editor. PC400 does not support
combined communication options (e.g., phone-to-RF),
PakBus® routing, or scheduled data collection.
RTDAQ is an ideal solution for industrial and real-
time users desiring to use reliable data collection
so ware over a single telecommunications medium,
and who do not rely on scheduled data collection.
RTDAQs strength lies in its ability to handle the
display of high speed data.
LoggerNet is Campbell Scienti c’s full-featured datalog-
ger support so ware. It is referred to as “full-featured
because it provides a way to accomplish almost all the
tasks youll need to complete when using a datalogger.
LoggerNet supports combined communication options
(e.g., phone-to-RF) and scheduled data collection.
The Network Planner, included in LoggerNet 4 or higher, gener-
ates device settings and con gures the LoggerNet network map
for PakBus networks.
Both LoggerNet and RTDAQ use View Pro to display historical
data in a tabular or graphical format.
The CR1000 is compatible with the AM16/32B (shown above)
and AM25T multiplexers.