Campbell SC-USB Bedienungsanleitung Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
2
The CR1000 provides precision measurement capabilities in a rugged, battery-operated package. It consists of a measurement and
control module and a wiring panel. Standard operating range is -25° to +50°C; an optional extended range of -55° to +85°C is available.
*Originally, the standard CR1000 had 2 MB of data/program storage, and an optional version, the CR1000-4M, had 4 MB of memory. In September
2007, the standard CR1000 started having 4 MB of memory, making the CR1000-4M obsolete. Dataloggers that have a module with a serial num-
ber greater than or equal to 11832 will have a 4 MB memory.  e 4 MB dataloggers will also have a sticker on the canister stating “4M Memory”.
CR1000
Measurement and Control System
Input/Output Terminals
Individually configured
for ratiometric resistive
bridge, thermocouple,
switch closure, high fre-
quency pulse, low-level ac,
serial sensors, and more.
CS I/O Port—connects with
AC-powered PCs and com-
munication peripherals such
as phone, RF, short-haul, and
multidrop modems.
RS-232—provides
a 9-pin DCE port
for connecting a
battery-powered
laptop, serial
sensors or RS-232
modems.
Removable Power Terminal—simpli es
connection to external power supply.
Peripheral Port—allows data to be
stored on a CompactFlash card and/or
supports Ethernet communications.
{
Features
4 Mbyte memory*
Program execution rate of up to 100 Hz
CS I/O and RS-232 serial ports
13-bit analog to digital conversions
16-bit H8S Renesas Microcontroller with 32-bit
internal CPU architecture
Temperature compensated real-time clock
Background system calibration for accurate mea-
surements over time and temperature changes
Single DAC used for excitation and measurements
to give ratio metric measurements
Gas Discharge Tube (GDT) protected inputs
Data values stored in tables with a time stamp and
record number
Battery-backed SRAM memory and clock ensuring
data, programs, and accurate time are maintained
while the CR1000 is disconnected from its main
power source
Serial communications with serial sensors and
devices supported via I/O port pairs
P B, Modbus, DNP3, TCP/IP, FTP, and SMTP
protocols supported
Measurement and Control Module
e module measures sensors, drives direct communi-
cations and telecommunications, reduces data, con-
trols external devices, and stores data and programs in
on-board, non-volatile storage.  e electronics are RF
shielded and glitch protected by the sealed, stainless
steel canister. A battery-backed clock assures accurate
timekeeping.  e module can simultaneously provide
measurement and communication functions.  e
on-board, BASIC-like programming language sup-
ports data processing and analysis routines.
Wiring Panel
e CR1000WP is a black, anodized aluminum wiring
panel that is compatible with all CR1000 modules.  e
wiring panel includes switchable 12 V, redistributed
analog grounds (dispersed among analog channels
rather than grouped), unpluggable terminal block for
12 V connections, gas-tube spark gaps, and 12 V sup-
ply on pin 8 to power our COM-series phone modems
and other peripherals.  e control module easily dis-
connects from the wiring panel allowing  eld replace-
ment without rewiring the sensors. A description of
the wiring panels input/output channels follows.
Seitenansicht 1
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare