INSTRUCTION MANUAL NL115 Ethernet and CompactFlash® Module Revision: 4/15 Copyright © 2006- 2015 Campbell Scientific, Inc.
NL115 Ethernet and CompactFlash® Module • An NL115 with a serial number less than 10297 requires a firmware update to function properly when attached
NL115 Ethernet and CompactFlash® Module 4.2 Communicating via Ethernet 4.2.1 Step 1: Configure Datalogger a. Connect serial cable from PC COM port
NL115 Ethernet and CompactFlash® Module 4.2.2 Step 2: LoggerNet Setup The next step is to run LoggerNet and configure it to connect to the datalogger
NL115 Ethernet and CompactFlash® Module 4.2.3 Step 3: Connect You are now ready to connect to your datalogger using the LoggerNet Connect Screen. D
NL115 Ethernet and CompactFlash® Module 4.4 CF Card Data Retrieval Data stored on cards can be retrieved through a communication link to the datalogg
NL115 Ethernet and CompactFlash® Module 5.2 Power The Ethernet/CompactFlash module is powered by 12 Vdc received from the datalogger through the peri
NL115 Ethernet and CompactFlash® Module EMI and ESD Protection: Meets requirements for a class A device under European Standards Application of Cou
NL115 Ethernet and CompactFlash® Module 7. Operation 7.1 TCP/IP Functionality This section describes the main TCP/IP functionality of a datalogger w
NL115 Ethernet and CompactFlash® Module SendVariables (Result1,Socket,-1,4094,0000,100,"Public","Callback",dummy1,1) Call
NL115 Ethernet and CompactFlash® Module 7.1.2 HTTP Web Server Typing the datalogger’s IP address into a web browser will bring up its home page, as s
NL115 Ethernet and CompactFlash® Module 7.1.3 FTP 7.1.3.1 FTP Server With an NL115 attached, the datalogger will automatically run an FTP server. T
NL115 Ethernet and CompactFlash® Module FIGURE 7-3. FTP CRD directory In order to use FTP, the datalogger’s FTP User Name and FTP Password must be s
NL115 Ethernet and CompactFlash® Module b. Open a Windows Explorer window. Enter ftp://username:[email protected] where nnn.nnn.nnn.nnn is th
NL115 Ethernet and CompactFlash® Module 7.1.6.1 Serial Input The TCPOpen() instruction must be used first to open up a TCP socket. An example of thi
NL115 Ethernet and CompactFlash® Module powered up with the NL115 attached and Ethernet cable plugged in. The IP address can be found with the Device
NL115 Ethernet and CompactFlash® Module Power-up functions of CompactFlash® cards can include: a) Sending programs to the CR1000 or CR3000 b) Settin
NL115 Ethernet and CompactFlash® Module Device = the device to which the associated file will be copied Options are CPU:, USR:, and CRD:. If left b
NL115 Ethernet and CompactFlash® Module 7.2.3.3 Program Execution After File is processed, the following rules determine what datalogger program to r
NL115 Ethernet and CompactFlash® Module 7.2.4 Camera Files JPEG images taken by a CC640 digital camera (retired) connected to the datalogger can be s
NL115 Ethernet and CompactFlash® Module PROGRAM 'CR1000 Public temp DataTable (Table1,1,-1) CardOut (0, -1) Maximum (1,temp,FP2,False,False
Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service
NL115 Ethernet and CompactFlash® Module Tables 3 and 4 will output the maximum and minimum of the panel temperature and battery voltage to the card ev
NL115 Ethernet and CompactFlash® Module 7.4 CF Card Data-Retrieval Details Data stored on CF cards can be retrieved through a communication link to t
NL115 Ethernet and CompactFlash® Module To remove a card, press the Initiate Removal button on the NL115. The datalogger will transfer any buffered d
NL115 Ethernet and CompactFlash® Module 7.4.2.2 Reinserting the Card If the same card is inserted again into the NL115, the datalogger will store all
NL115 Ethernet and CompactFlash® Module 26
Appendix A. CF Card Maintenance A.1 Formatting CF Card The CF card can be formatted using 1) Windows Explorer, 2) the CR1000KD, or 3) LoggerNet Fil
Appendix A. CF Card Maintenance 5) Choose FAT32 under file system, give the card a label, and press Start. (The datalogger will work with either FA
Appendix A. CF Card Maintenance 3) Choose FileControl under the Tools menu of the Connect Screen. 4) Highlight CRD. 5) Press Format. 6) Press Y
Appendix A. CF Card Maintenance 5) Navigate to the Tools tab. 6) Press Check Now. 7) Select both options. 8) Press Start. A-4
Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe
Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO
Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec
Table of Contents 7.2.3.2 Applications ...... 18 7.2.3.3 Program Execution ...
NL115 Ethernet and CompactFlash® Module 1. Introduction Campbell Scientific’s NL115 Ethernet/CompactFlash® Module provides two independent capabilit