INSTRUCTION MANUAL NL115 Ethernet and CompactFlash® Module Revision: 4/15 Copyright © 2006- 2015 Campbell Scientific, Inc.

Seite 2

NL115 Ethernet and CompactFlash® Module • An NL115 with a serial number less than 10297 requires a firmware update to function properly when attached

Seite 3 - Limited Warranty

NL115 Ethernet and CompactFlash® Module 4.2 Communicating via Ethernet 4.2.1 Step 1: Configure Datalogger a. Connect serial cable from PC COM port

Seite 4 - Assistance

NL115 Ethernet and CompactFlash® Module 4.2.2 Step 2: LoggerNet Setup The next step is to run LoggerNet and configure it to connect to the datalogger

Seite 5 - Precautions

NL115 Ethernet and CompactFlash® Module 4.2.3 Step 3: Connect You are now ready to connect to your datalogger using the LoggerNet Connect Screen. D

Seite 6

NL115 Ethernet and CompactFlash® Module 4.4 CF Card Data Retrieval Data stored on cards can be retrieved through a communication link to the datalogg

Seite 7 - Table of Contents

NL115 Ethernet and CompactFlash® Module 5.2 Power The Ethernet/CompactFlash module is powered by 12 Vdc received from the datalogger through the peri

Seite 8 - Figures

NL115 Ethernet and CompactFlash® Module EMI and ESD Protection: Meets requirements for a class A device under European Standards Application of Cou

Seite 9 - 2. Cautionary Statements

NL115 Ethernet and CompactFlash® Module 7. Operation 7.1 TCP/IP Functionality This section describes the main TCP/IP functionality of a datalogger w

Seite 10 - 4. Quickstart

NL115 Ethernet and CompactFlash® Module SendVariables (Result1,Socket,-1,4094,0000,100,"Public","Callback",dummy1,1) Call

Seite 11 - (p. 15)

NL115 Ethernet and CompactFlash® Module 7.1.2 HTTP Web Server Typing the datalogger’s IP address into a web browser will bring up its home page, as s

Seite 13 - 4.2.3 Step 3: Connect

NL115 Ethernet and CompactFlash® Module 7.1.3 FTP 7.1.3.1 FTP Server With an NL115 attached, the datalogger will automatically run an FTP server. T

Seite 14 - 5. Overview

NL115 Ethernet and CompactFlash® Module FIGURE 7-3. FTP CRD directory In order to use FTP, the datalogger’s FTP User Name and FTP Password must be s

Seite 15 - 6. Specifications

NL115 Ethernet and CompactFlash® Module b. Open a Windows Explorer window. Enter ftp://username:[email protected] where nnn.nnn.nnn.nnn is th

Seite 16

NL115 Ethernet and CompactFlash® Module 7.1.6.1 Serial Input The TCPOpen() instruction must be used first to open up a TCP socket. An example of thi

Seite 17 - 7. Operation

NL115 Ethernet and CompactFlash® Module powered up with the NL115 attached and Ethernet cable plugged in. The IP address can be found with the Device

Seite 18

NL115 Ethernet and CompactFlash® Module Power-up functions of CompactFlash® cards can include: a) Sending programs to the CR1000 or CR3000 b) Settin

Seite 19 - 7.1.2 HTTP Web Server

NL115 Ethernet and CompactFlash® Module Device = the device to which the associated file will be copied Options are CPU:, USR:, and CRD:. If left b

Seite 20 - 7.1.3 FTP

NL115 Ethernet and CompactFlash® Module 7.2.3.3 Program Execution After File is processed, the following rules determine what datalogger program to r

Seite 21 - (p. 3) (Step 1 only)

NL115 Ethernet and CompactFlash® Module 7.2.4 Camera Files JPEG images taken by a CC640 digital camera (retired) connected to the datalogger can be s

Seite 22 - 7.1.6 Serial Server

NL115 Ethernet and CompactFlash® Module PROGRAM 'CR1000 Public temp DataTable (Table1,1,-1) CardOut (0, -1) Maximum (1,temp,FP2,False,False

Seite 23 - 7.1.8 DHCP

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Seite 24 - 7.2 File Formats

NL115 Ethernet and CompactFlash® Module Tables 3 and 4 will output the maximum and minimum of the panel temperature and battery voltage to the card ev

Seite 25

NL115 Ethernet and CompactFlash® Module 7.4 CF Card Data-Retrieval Details Data stored on CF cards can be retrieved through a communication link to t

Seite 26

NL115 Ethernet and CompactFlash® Module To remove a card, press the Initiate Removal button on the NL115. The datalogger will transfer any buffered d

Seite 27

NL115 Ethernet and CompactFlash® Module 7.4.2.2 Reinserting the Card If the same card is inserted again into the NL115, the datalogger will store all

Seite 28 - 7.3 Programming

NL115 Ethernet and CompactFlash® Module 26

Seite 29

Appendix A. CF Card Maintenance A.1 Formatting CF Card The CF card can be formatted using 1) Windows Explorer, 2) the CR1000KD, or 3) LoggerNet Fil

Seite 30 - 7.3.3 Table Size and Mode

Appendix A. CF Card Maintenance 5) Choose FAT32 under file system, give the card a label, and press Start. (The datalogger will work with either FA

Seite 31

Appendix A. CF Card Maintenance 3) Choose FileControl under the Tools menu of the Connect Screen. 4) Highlight CRD. 5) Press Format. 6) Press Y

Seite 32

Appendix A. CF Card Maintenance 5) Navigate to the Tools tab. 6) Press Check Now. 7) Select both options. 8) Press Start. A-4

Seite 34

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Seite 35 - A.1 Formatting CF Card

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Seite 36 - A.1.2 CR1000KD

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Seite 38

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Seite 39

Table of Contents 7.2.3.2 Applications ...... 18 7.2.3.3 Program Execution ...

Seite 40

NL115 Ethernet and CompactFlash® Module 1. Introduction Campbell Scientific’s NL115 Ethernet/CompactFlash® Module provides two independent capabilit

Kommentare zu diesen Handbüchern

Keine Kommentare