Seite 1 - RavenXTG GPRS/EDGE

RavenXTG GPRS/EDGESierra Wireless Cellular ModemRevision: 12/13 Copyright © 2006-2013Campbell Scientific, Inc.

Seite 2

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem • PN 14394 Raven Mounting Kit—includes mounting hardware for securing the modem to below-referenced

Seite 3 - Warranty

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem PN 20679 Omni Directional Antenna PN 18285 1 dBd Omni Directional Antenna PN 14454 9dBd Direction

Seite 4 - Assistance

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem • Power Supply (see power considerations). • Environmental Enclosure—ENC10/12, ENC12/14, or ENC16/

Seite 5 - Table of Contents

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 4.3.2 Modem Connections Using the SC105 .3.2 Modem Connections Using the SC105 The SC105 interface

Seite 6 - Figures

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 4.3.3 Modem Connections Using the SC932A .3.3 Modem Connections Using the SC932A The SC932A interf

Seite 7 - Cellular Modem

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 4.4 Power Considerations A power cable included with the modem connects to the datalogger’s 12 V or

Seite 8 - 3. Specifications

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem Indicator Lights When your RavenXTG is connected to power and an antenna, there is a specific patter

Seite 9 - 4. Configuration

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem • Authentication Failure—The Network, Signal, and Activity LEDs blink every 2 seconds. Contact the

Seite 10

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem Connect the RavenXTG to a COM port on the PC with a direct RS-232 cable. Also connect the antenna a

Seite 11

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem Click the Load icon in the Configuration Panel. When prompted for a template file name, select “Rav

Seite 13

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem Click on EDGE/HSDPA Group to get the following screen: For a data account with the I2GOLD APN, ente

Seite 14

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 5.1 Configuring the RavenXTG for Dynamic IP Accounts with the I2GOLD APN are provided with a Static

Seite 15 - 4.4 Power Considerations

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 1. Modem name: A unique name for the modem (the 10-digit MDN number is recommended). 2. Domain: T

Seite 16

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 6. LoggerNet/PC400 Software Setup The Loggernet “Device Map” is configured from the “Setup” button

Seite 17

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem Example settings for a “Dynamic IP” address: For a Dynamic IP using Sierra Wireless’s IP Manag

Seite 18

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 5. For PakBus dataloggers, set the PakBus address to match that of the datalogger (default address

Seite 19

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 7. Troubleshooting Please refer to Appendix E, Troubleshooting Flowchart, for additional troublesh

Seite 20

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem f. If you have a Static IP account, verify the Static IP Address. Preceding zeros in the IP addres

Seite 21

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem c. Select the “Serial” Group, and make sure the “AT Verbose Mode” is set to “Numeric” for use with

Seite 22

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem Verify the APN has been entered in the NETAPN and +CGDCONT fields as shown above (where I2GOLD is th

Seite 23

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Seite 24

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 2. Check your LoggerNet setup. a. Make sure the port number at the end of the IP address matches t

Seite 25

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 3. Use AceManager to check modem communications with datalogger. The modem’s “Host Serial Bytes Se

Seite 26 - 7. Troubleshooting

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 26

Seite 27

Appendix A. AceManager Setup without Template File AceManager is used to program settings in the RavenXT modems to make the modems compatible with C

Seite 28

Appendix A. AceManager Setup without Template File • S23 — Configure Serial Port — The baud rate needs to be configured to match a valid datalogger

Seite 29

Appendix B. Installation of SIM Card in the RavenXTG The Subscriber Identity Module (SIM) in the RavenXTG is a smartcard securely storing the key id

Seite 30

Appendix B. Installation of SIM Card in the RavenXTG 4. Replace the faceplate; the installation of the SIM is complete. B-2

Seite 31

Appendix C. Configuring the RavenXTG Modem for PPP Settings in the RavenXTG and datalogger (CR800, CR1000, and CR3000), can be changed to configure

Seite 32

Appendix C. Configuring the RavenXTG Modem for PPP • MD = 02-PPP C-2

Seite 33

Appendix C. Configuring the RavenXTG Modem for PPP Datalogger Settings: Using the Device Configuration Utility, configure the following setting on th

Seite 34

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Seite 35

Appendix C. Configuring the RavenXTG Modem for PPP Using the Device Configuration Utility, select the “Network Services” tab. The “PakBus/TCP Servic

Seite 36

Appendix C. Configuring the RavenXTG Modem for PPP LoggerNet Settings: Enter the IP address of the RavenXTG, and the PakBus/TCP Service Port number o

Seite 37 - Modem for PPP

Appendix C. Configuring the RavenXTG Modem for PPP C-6

Seite 38 - • MD = 02-PPP

Appendix D. EmailSend Using the Gmail Outgoing SMTP Server The datalogger has a mail client in it similar to a mail client on a computer. For the d

Seite 39

Appendix D. EmailSend Using the Gmail Outgoing SMTP Server D.3 Sending a Text Message to a Phone To send a text message to a phone, the email needs

Seite 40

Appendix D. EmailSend Using the Gmail Outgoing SMTP Server If Temp > 27 Then AlarmTrigger = True If AlarmTrigger Then Message = "Warning!&quo

Seite 41

Appendix D. EmailSend Using the Gmail Outgoing SMTP Server D-4

Seite 42

Appendix E. Troubleshooting Flowchart Is Network LED on solid? Not provisioned/registered on network. Verizon or AT&T? Check coverage map. Are

Seite 43 - Gmail Outgoing SMTP Server

Appendix E. Troubleshooting Flowchart Can’t connect, Network light is solid... Check signal strength (should be between -51 (strong) and -91 (weak).

Seite 44

Appendix E. Troubleshooting Flowchart PPP or Serial Server Can’t connect, Network light is solid... (cont.) Have mobile terminated IP Was correct te

Seite 45

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Seite 46

Appendix E. Troubleshooting Flowchart Was SIM card installed? Can’t connect, AT&T...(cont. from page D-1) No Was correct template loaded in AceM

Seite 47 - Flowchart

Appendix E. Troubleshooting Flowchart PPP or Serial Server? One computer can connect, other(s) cannot... In this mode, it’s first come, first serve,

Seite 48

Appendix E. Troubleshooting Flowchart E-6

Seite 50 - (cont. from page D-1)

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Seite 51

Table of Contents ii D. EmailSend Using the Gmail Outgoing SMTP Server...D-1 D.1

Seite 52

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem 1. General Description This manual provides information for interfacing the Sierra Wireless RavenX

Seite 53

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem Blu-Telecommunication is part of the Alliance Channel with AT&T, and can assist any customer nat

Seite 54

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem Typical Current Drain (at 12 Vdc): 50 mA dormant (idle for 10 to 20 seconds), 120 mA transmit/r

Kommentare zu diesen Handbüchern