SP Lite2 Silicon Pyranometer
2. Sensor Specifications
Electrical
Nominal Impedance: > 10:
Response Time: <1 second (at 95%)
Sensitivity: (see Certificate of Calibration
that was shipped with sensor)
Expected signal range: 0 – 120 mV
(under atmospheric conditions)
Sensitivity: ±2% shift per year
Non-linearity: ±1% between 0 to 1000 W m
-2
Temperature dependence
of sensitivity: ±0.15% °C
Spectral
Spectral range: 400 to 1100 nm
Detector type: BPW 34
Directional
Cosine corrected between
8qangle of incidence, error: within ±5%
Cosine errors averaged over opposite
azimuth error (at 6qangle of incidence): within ±5%
Tilt response: zero error
Mechanical
Housing material: Anodized aluminum
Cable material: Polyurethane
Weight: 110 g
Cable length: 5 m (can be extended up to 100 m)
Physical Dimensions: See Figure 5
Environmental
Working temperature: -40 to +8°C
Dimensions
FIGURE 5. Dimensions of SP Lite2 with Leveling Device