5
Compatible Sensors**
e CR200X-series dataloggers can measure a variety
of sensors including SDI-12 sensors and 4 to 20 mA
sensors. e parameters and sensors in which the
CR200X series can measure are listed below:
AC• Current—CS15 Current Transformer. Our
CS10 is not compatible.
Barometric• Pressure—CS100 and CS106 baro-
metric pressure sensors.
Evaporation• —255-100 Evaporation Gauge.
Leaf• Wetness—237 and LWS leaf wetness sensors.
Multiparameter• —WXT520 Weather Transmitter.
Precipitation• —TE525, TE525WS, TE525MM,
TB4, TB4MM, CS700, and 52202 tipping bucket
rain gages.
Relative• Humidity—CS215, HMP60, HMP45C,
and HMP155A air temperature and relative hu-
midity probes.
Snow• Depth—SR50A Sonic Ranging Sensor.
Soil• Volumetric Water Content— EasyAG probe,
EnviroSCAN probe, CS650 re ectometer, and
CS625 re ectometer. Our CS616 is not compatible.
Solar• Radiation—CS300 Pyranometer. Our
LI200X, LI190SB, LP02, CMP3, NR-LITE2, NR01,
CNR4, and CNR2 probes are not compatible.
Te m p e ra t u r e• —109, 109SS, and 110PV thermistors.
Other temperature probes listed on our price lists in-
cluding our 107/108 thermistors and thermocouples
are not compatible.
Wate r• Level—CS450, CS455, and CS460 pres-
sure transducers; CS410 Sha Encoder; CS470
and CS471 compact bubblers; CS475, CS476,
and CS477 pulse radar sensors, and SR50A Sonic
Ranging Sensor. Our CS431 pressure transducer
is not compatible.
Wate r• Quality—CS525 ISET pH probe, OBS-3+
turbidity probe, OBS3A turbidity probe, CS511
Dissolved Oxygen Probe, 109 Temperature Probe,
and 109SS Temperature Probe. Our CS547A,
CSIM11, CSIM11-ORP, 107, and 108 probes are
not compatible.
Wind•
Speed and Direction—014A, 034B, 03101,
03002, 05103, 05106, 05305, 27106T, and Wind-
Sonic4 sensors. e WindSonic1 and CSAT3 are
not compatible.
** e CR200X-series dataloggers can not make di erential measurements. ey are not compatible with the freezing-rain/ice, fuel moisture/
temperature, geographic position, present weather, soil heat ux, soil matric water potential, and strain sensors listed on our price lists. Campbell
Scienti c’s SDM devices and multiplexers are also not supported.
CS625
CS625
The CS15 consists of a CR Magnetic’s CR8459 Current Trans-
former that was modi ed to measure the approximate current
over a 0 to 125 A range.
The CS625 Water Content
Re ectometer has a 0 to 3.3 V
square wave frequency output.
The 109 thermistor can measure air, water, or soil temperature
from -50° to +70°C. This probe outputs a signal of 0 to 2.2 volts.
Kommentare zu diesen Handbüchern