CS225 Temperature String
5
5.2 CS225 Temperature String
Operating Range: -55q to +85qC
Accuracy: Typical - r2qC over -40q to +85qC,
Worst-case - rqC over -40q to +85qC;
±0.5qC over -55qWRqC
(includes lifetime drift of sensor)
Resolution: 0.0078qC
Measurement Update
Interval: 1 second (automatic), occurs in quiescent mode
Warm-up Time: 10 seconds
Maximum Sensors
per String: 36 sensors
Maximum Pressure: 50 PSI
Supply Voltage: 9 to 28 Vdc
Current Consumption: Quiescent: # sensors * 1.0 mA (max)
Active (during SDI-12 communications): 20 mA +
(# sensors * 1.0 mA)
Temperature Point
Diameter: 2.22 cm (0.875 in)
Maximum Cable
Length: 152 m (500 ft), individual CS225 and datalogger
SDI-12 terminal maximum
Minimum Sensor
Spacing: 15cm (5.9 in)
The furthest temperature point from the datalogger (or the
temperature point at the end of the string) is addressed starting at
‘1’. Each temperature point going up the string towards the
datalogger changes by one address number/letter.