Interfacing the MICROCOM DESIGN GTX Modulator to the Campbell Scientific CR1000 Data Logger PRELIMINARY
© 2005 Microcom Design Inc. All rights reserved voice: 401.771.1070 Fax:410.771.0018
uAPP222 (v1.0) July 12, 2005 http://www.microcomdesign.com 19
BeginProg
'Initialize
Call Initialize()
'Execution loop
Scan(10,msec,1,0)
SerialThru() ‘ call pass through code
'Take other measurements as needed
'Default Datalogger Battery Voltage measurement Batt_Volt:
Battery(Batt_Volt)
'
‘
‘
‘
NextScan
EndProg
Conclusion
The MICROCOM Model GTX Satellite Transmitter and Data collector has some
internal data logger capability. For more advanced data acquisition, The GTX
can be interfaced to external data loggers like the CR1000 from Campbell
Scientific. This application note showed various ways of connecting up and
debugging the interface between the GTX and the CR1000.
Revision
History
Date Version Revision
July 12, 2005 1.0 Initial Microcom Preliminary Release
Kommentare zu diesen Handbüchern