Interfacing the MICROCOM DESIGN GTX Modulator to the Campbell Scientific CR1000 Data Logger PRELIMINARY
SerialOut (Com4,"RandomData=","",0,100)
SerialOut (Com4,batt_volt,"",0,100)
' Echo stuff to Debug Terminal
If DebugOnOff = 1 Then
SerialOut(Com1,Mess1,"",0,0)
SerialOut (Com1,"RandomData=","",0,100)
SerialOut (Com4, CRLF,"",0,100)
SerialOut (Com1,batt_volt,"",0,100)
SerialOut (Com1, CRLF,"",0,100)
EndIf
' Get responce from GTX
SerialIn (InString,Com4,100,10,100)
' Echo stuff to Debug Terminal
If DebugOnOff = 1 Then
SerialOut(Com1,Mess2,"",0,0)
SerialOut (Com1,InString,"",0,100)
EndIf
' Get responce from GTX
SerialIn (InString,Com4,100,10,100)
' Echo stuff to Debug Terminal
If DebugOnOff = 1 Then
SerialOut (Com1, CRLF,"",0,100)
SerialOut(Com1,Mess2,"",0,100)
SerialOut (Com1,InString,"",0,100)
EndIf
' Send CRs until getting Com4 > " >"
SerialOut (Com4,CR,">",100,100)
' Send Temperature to the Com4 in a Random Data Command
SerialOut (Com4,"RandomData=","",0,100)
SerialOut (Com4,"Temp:"+PTemp,"",0,100)
' Echo stuff to Debug Terminal
If DebugOnOff = 1 Then
SerialOut(Com1,Mess1,"",0,0)
SerialOut (Com1,"RandomData=","",0,100)
SerialOut (Com4, CRLF,"",0,100)
SerialOut (Com1,"Temp: "+PTemp,"",0,100)
SerialOut (Com1, CRLF,"",0,100)
EndIf
' Get responce from GTX
SerialIn (InString,Com4,100,10,100)
' Echo stuff to Debug Terminal
If DebugOnOff = 1 Then
SerialOut(Com1,Mess2,"",0,0)
SerialOut (Com1,InString,"",0,100)
EndIf
' Get responce from GTX
SerialIn (InString,Com4,100,10,100)
' Echo stuff to Debug Terminal
If DebugOnOff = 1 Then
SerialOut (Com1, CRLF,"",0,100)
SerialOut(Com1,Mess2,"",0,100)
SerialOut (Com1,InString,"",0,100)
EndIf
' Get Time from GTX
Call GetGTXTime()
' Set CR1000 Station CLock to the new values
ClockSet (myTime())
NextScan
EndProg
© 2005 Microcom Design Inc. All rights reserved voice: 401.771.1070 Fax:410.771.0018
uAPP222 (v1.0) July 12, 2005 http://www.microcomdesign.com 13