Model CS205 10-hour Fuel Temperature Stick
5.2 CR10X Programming
;{CR10X}
*Table 1 Program
01: 10 Execution Interval (seconds)
1: Temp (107) (P11)
1: 1 Reps
2: 1 SE Channel
3: 21 Excite all reps w/E1, 60Hz, 10ms delay
4: 1 Loc [ T107_C ]
5: 1.0 Multiplier
6: 0.0 Offset
3: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
4: Set Active Storage Area (P80)
1: 1 Final Storage Area 1
2: 101 Array ID
5: Real Time (P77)
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
6: Average (P71)
1: 1 Reps
2: 1 Loc [ T107_C ]
6. Maintenance and Calibration
The 107 Probe requires minimal maintenance. Please refer to the 107 manual
for more detail.
The CS205 Fuel Moisture Stick should be changed annually or more
frequently as required. The wood should visually appear fresh and new not
gray or discolored.
FIGURE 6-1. 107 Thermistor Probe Schematic