Campbell PC208W Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 62
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
12
Data Retrieval, Processing and Final Storage in the Lake Victoria Basin Database
Step
Operation
Hardware Involved
User Action
1
~ Periodic automatic measurement of
hydro-meteorologic paremeters
~ pre-processing and storage in the
datalogger’s RAM
Sensors + Datalogger
None
2
Transfer of accumulated measurements
from logger’s RAM to portable SM192
Storage Module; each single transfer
exercise results in a separate data file
Datalogger + SM192
Storage Module +
CR10KD Keyboard
Display
- Connect SM192 to datalogger
- Type in proper keyboard
commands
The user can choose between
automatic or manually invoked data
transfer
3
Transfer of data files from SM192
Storage Module to PC
SM192 Storage
Module + SC532
Interface + PC
- Connect SM192 to SC532
- Activate StgModule Software
- Establish connection between PC
and SM192
- Invoke data transfer
4
Separating and/or rearranging individual
hydro-meteorological parameters from a
complete, original data file
PC
- Activate Report software
- Open a ppropriate pre-defined
parameter file
- Select input data file
- Run Split
- First, visual data quality check
5
Exporting separated/rearranged hydro-
meteorological parameters to comma
separated ASCII file
PC
- Activate Report software
- Open appropriate pre-defined
paremeter file
- Select input data file
- Select and define output data file
- Run Split
6
~ Importing comma separated ASCII
file into MS Access and restructuring
data to LVBD format
~ Initial (automatic) quality control
PC
- Activate MS Access
- Open appropriate database file
- Import ASCII file in predefined
table
- Activate predefined query to
restructure data format
7
Final Storage in the LVBD
PC
- Copy contents of above mentioned
query results to the clip board
- Open appropriate LVBD file
- Open appropriate table
- Add data using paste -append
8
Further quality control of newly added
data
PC
- Open appropriate LVBD file
- Open appropriate table
- Run pre-defined data-quality-
control queries
9
Back-up and data dissemination
PC + modem +
telephone
The various user actions involved in
this step will be discussed and
elaborated in a separate document.
Table 1: Comprehensive Data Trajectory
Detailed Outline of Data Trajectory
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 61 62

Kommentare zu diesen Handbüchern

Keine Kommentare