Campbell SDM-SIO4 Bedienungsanleitung Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
3
e SDM-CD16D increases the number of digital
outputs that can be controlled (i.e., set to 0 or 5 Vdc)
by a Campbell datalogger.  e SDM-CD16D is com-
monly used to drive normal logic level inputs. It can
also source some current; when an output is set HI,
a ‘boost’ circuit allows the SDM-CD16D to source a
current of up to 100 mA, which allows it to directly
control low voltage valves, relays, etc.
SDM-CD16D 16-Channel Digital Control Port Expansion Module
SDM-CD16S 16-Channel Solid State DC Relay Controller Module
e SDM-CD16S is a 16-channel, solid-state relay
driver that can control devices that have a relatively
high-powered load such as solenoids, solenoid valves,
dc motors, stepper motors, lights, horns, heaters,
and fans. With a voltage range of up to 48 Vdc and
a maximum current output per channel of 2 A, the
SDM-CD16S can drive up to 100 W of power on each
channel. Separate inputs for power-to-outputs (48 Vdc
maximum) and power-to-SDM-CD16S logic (7 to
48 Vdc) allow the option of powering the logic from
the datalogger’s 12 V while switching a higher voltage.
SDM-CD16AC 16-Channel AC/DC Relay Controller
e SDM-CD16AC has 16 switchable ac/dc relays
for control of ac or dc devices. Each port is logically
controlled by the datalogger; toggle switches provide
manual override capability. An LED indicates when
each port is active. Ports can be controlled individu-
ally or in groups. A 12 Vdc external power supply is
recommended.  e SDM-CD16AC is UL approved.
UL/CUL contact ratings:
DC devices: 5 A @ 30 Vdc, 0.3 A @ 110 Vdc
AC devices: 5 A @ 125 Vac (1/10 hp),
5 A @ 277 Vac (1/6 hp).
Seitenansicht 2
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare