A static IP account. Although use of a dynamic IP account is
possible, Campbell Scientific strongly suggests establishing
a static account. To use a dynamic account, a service such as
IP Manager is required to translate the dynamic IP address
to a domain name so that the Raven110 can be contacted as
if it had a static IP address.
Feature code “G821” to be added to the account. Feature
Code G821 configures the account for the "Internet" Access
Point Name (APN), and the device to "Mobile Terminated",
which makes the modem accessible by LoggerNet over
the Internet. Feature Code G821 may also be added after
the account has been set up.
• AT&T can also setup a custom APN, which will take four to six
weeks and cost about $1000.00. A custom APN may offer more
efficient routing, and better security.
• AT&T will provide a SIMM card for each modem. In some
cases the SIMM card can be picked up at a local AT&T store.
The SIMM card must be installed inside of the modem (see
Appendix B of the manual).
Datalogger Site Equipment
• Raven110 Modem—includes a power cable. The following
software is used to program the modem:
Airlink's SetupWizard—activates the modem. It is pro-
vided on a CD that is shipped with the Raven110 and is
also available, at no charge, from: www.airlink.com
Airlink's Wireless Ace Software—configures the generic
parameters of the modem. It is provided on a CD that is
shipped with the Raven110 and is also available, at no
charge, from: www.airlink.com
Campbell Scientific's Raven GPRS/EDGE Template—used
with the Wireless Ace software to configure the modem. This
template sets up the Raven serial interface, which is specific
to our systems. The Raven GPRS/EDGE Template is avail-
able, at no charge, from: www.campbellsci.com/downloads
• Campbell Scientific Datalogger—all of our contemporary
and many of our retired dataloggers are compatible.
• Datalogger connection options:
The #18663 null modem cable—connects the modem
to the datalogger's RS-232 port.
An SC105 or SC932A interface—connects the modem
to the CS I/O port.
The #18663 null modem cable connects directly
to the datalogger's RS-232 port. This cable
is the only option available for connecting a
Raven110 modem to a CR200-series datalogger.
The SC105 interface connects the modem to
the datalogger's CS I/O port, and is recom-
mended when using a PAKBUS
®
datalogger.
The SC932A interface connects the modem to
the datalogger's CS I/O port, and is recom-
mended when using a mixed-array datalogger.
Cellular Coverage/Service Requirements
AT&T GPRS or EDGE network with coverage at the datalogger site (for a coverage map, refer to
www.wireless.att.com/refresh/common/estore_zipcode_maps).
• Call AT&T at 1-800-331-0500 and ask for the following:
A "Data Plan" (three options are offered)