CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) Issued: 17.6.14 Copyright © 2013-14 Campbell Scientific

Seite 3 - Guarantee

1 CS-GSM/GPRS digital transceiver kits This manual provides the details of how to use the CS-GSM/GPRS digital transceiver kits with Campbell Scientifi

Seite 4

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 2 protocol is supported either using the built-in TCP/IP capability of some Campbel

Seite 5 - PLEASE READ FIRST

Using with Campbell Scientific Dataloggers 3 4. Connect the power supply to the COM110A modem, by connecting the red/black power lead either directly

Seite 6

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 4 4. Connect the modem to the PC using the programming cable (use a serial to US

Seite 7 - Contents

Using with Campbell Scientific Dataloggers 5 for a direct connection to the serial port, CS I/O ME for the SC-WMI or one of the SDC options to match t

Seite 8

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 6 9. Turn on the power to the datalogger and COM110A modem. The status LED on the

Seite 9

Using with Campbell Scientific Dataloggers 7 mode (see Appendix D for more information). Your airtime provider will normally supply you with an extra

Seite 10

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 8 If you cannot use a base station GSM modem, lower cost calls may also be possible

Seite 11 - 1. Introduction

Using with Campbell Scientific Dataloggers 9  Can synchronise the datalogger clock to Internet time (networktimeprotocol).  Can send data to other

Seite 13

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 10 searching for “Fixed IP SIM” on the internet making sure the offering is not a 3

Seite 14

Using with Campbell Scientific Dataloggers 11 dynamic name service in this instance (please contact Campbell Scientific for more details). More common

Seite 15

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 12 significantly – the transmitter using an extra 100-400 mA depending on the insta

Seite 16

Using with Campbell Scientific Dataloggers 13 5.6 Sending configuration commands to the modem It is often advisable to reset the modem at regular i

Seite 17 - 4.2 GSM data call charges

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 14 The SC-WMI is not recommended for use where other devices are sharing the CS I/O

Seite 18 - 5. Using GPRS data transfer

Using with Campbell Scientific Dataloggers 15 The cable required for the direct connection to a datalogger serial port is supplied as part of the CS-G

Seite 19 - 5.1 Network coverage

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 16 6.4 Selecting and Connecting an Antenna When selecting an antenna, please note

Seite 20 - 5.3 GPRS Modes of operation

Using with Campbell Scientific Dataloggers 17 6.4.1 Antenna Supplied by Campbell Scientific Campbell Scientific can supply various antennas, if requi

Seite 21

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 18 Higher gain YAGI style antennas are available from Campbell Scientific to specia

Seite 22

Using with Campbell Scientific Dataloggers 19 This program is provided free of charge but is only licensed for use with COM110A modems purchased from

Seite 23

Guarantee This equipment is guaranteed against defects in materials and workmanship. This guarantee applies for twelve months from date of delivery.

Seite 24 - Diagram Not to Scale

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 20 Setup – Settings - Datalogger port: allows you to select the serial port on the

Seite 25 - 6.3 Connecting Power

Using with Campbell Scientific Dataloggers 21 less frequent than the default time of 60 mins then increase this time – at the possible cost of the ext

Seite 26

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 22 When this window is opened on the home screen an additional entry window app

Seite 27

Using with Campbell Scientific Dataloggers 23 8.1 Configuring a Desk-Top Modem as a Base Station You can use most desktop landline and even cellphone

Seite 28

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 24 To add this setting, use the Phone modem option in Loggernet where you can edit

Seite 29

Using with Campbell Scientific Dataloggers 25 Where the number of outgoing IP ports is limited, perhaps due to a firewall restriction, Pakbus loggers

Seite 30

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 26 9.2 Setting up call-back in Loggernet Where the logger is programmed to call

Seite 31

Using with Campbell Scientific Dataloggers 27 9.2.2 Setting up call-back in Loggernet Version 4 In Loggernet 4 there is a new root device called a Pa

Seite 32 - Data Assistant

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 28 You then need to attach a datalogger entry to the PakbusTCPServer for each data

Seite 33 - Loggernet

Using with Campbell Scientific Dataloggers 29 minutes or set up another process, e.g. low frequency pinging, to prevent the datalogger resetting the c

Seite 35

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 30 network. Generally, this will provide a reliable connection long term. However,

Seite 36

Using with Campbell Scientific Dataloggers 31 If the COM110A modem has definitely been registered on the GSM network, check that the registration is f

Seite 37

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 32  If you manually dial the number with a phone and hear a buzzing noise rather

Seite 38

Using with Campbell Scientific Dataloggers 33  Check the modem was configured correctly.  Check you have set the correct APN, username and passwor

Seite 39 - 9.2.4 Firewall Issues

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 34 Messages that can appear include: Message Cause/Fault ppp initialized PPP was en

Seite 40 - ENTER>. If the COM110A

Using with Campbell Scientific Dataloggers 35  Make sure any local firewalls allow you to make outgoing connections on the ports being used. (Some i

Seite 41

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 36 the logger settings first) Click on connect. This opens a dumb terminal emulato

Seite 42

A-1 Appendix A. Using the COM110A with the PIN Security Feature Enabled It is possible to use the COM110A with Campbell Scientific dataloggers with th

Seite 43

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) A-2 'Main Program BeginProg 'Normal measurements in the main scan here

Seite 44

Appendix A. Using the COM110A with the PIN Security Feature Enabled A-3 A3. CR10X Program Example Using Instruction P97 with the generic modem opti

Seite 45

PLEASE READ FIRST About this manual Some useful conversion factors: Area: 1 in2 (square inch) = 645 mm2 Length: 1 in. (inch) = 25.4 mm

Seite 46

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) A-4 2: 1 Disabled when User Flag 1 is High 3: 20 Seconds Call Time L

Seite 47 - PIN Security Feature Enabled

Appendix A. Using the COM110A with the PIN Security Feature Enabled A-5 2: 30 Then Do 12: If Flag/Port (P91) 1: 12 Do if Flag 2 is Hi

Seite 49 - A3. CR10X Program Example

B-1 Appendix B. Controlling the Power Supply to the COM110A Modem This Appendix describes how the datalogger can be used to control the power supply

Seite 50

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) B-2 B1.1 CRBasic Program Example of Power Control This example can be used on the

Seite 51

Appendix B. Controlling the COM110A Power Supply B-3 'First send the +++ sequence to get the modem in command mode - in case online

Seite 52

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) B-4 B.1.2 CR10X Program Example ;COM110A power control example code for the CR10X

Seite 53 - Supply to the COM110A Modem

Appendix B. Controlling the COM110A Power Supply B-5 CAUTION If power is limited and the turn-on time has to be kept very short, it is

Seite 55

C-1 Appendix C. Useful Configuration Commands for the COM110A This section gives details of some of the useful test commands that can be used during

Seite 57

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) C-2 C.2 Network Registration Checks AT+COPS Operator selection Test command AT+CO

Seite 58

Appendix C. Useful Configuration Commands C-3 AT+CREG Network registration Test command AT+CREG=? Response +CREG: list of supported <n>s OK Par

Seite 59 - Commands for the COM110A

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) C-4 C.3 PIN Configuration AT+CPIN Enter PIN Test command AT+CPIN=? Response OK Re

Seite 60 - Operator selection

Appendix C. Useful Configuration Commands C-5 To switch between EU/US band(s) for the COM110A, use a communication software such as a HyperTerminal,

Seite 62 - Enter PIN

D-1 Appendix D. Using the COM110A in Transparent Mode for GSM Dial-up use It is possible to use the COM110A in transparent mode, when the default non-

Seite 63

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) D-2

Seite 64

E-1 Appendix E. Resetting the COM110A Module under Program Control This Appendix describes how the datalogger can be used to send commands to the COM

Seite 65 - D.1 Introduction

CS-GSM Digital Transceiver Kits (including the COM110A modem) E-2 SlowSequence 'Run once a minute so can have one minute resolution of timin

Seite 66

Appendix E. Resetting the COM110A Under Program Control E-3 ; is loaded to as flag 8 will be low then. 1: If time is (P92) 1: 1439 Minutes (Se

Seite 67 - Module under Program Control

i Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to spe

Seite 69

F-1 Appendix F. Configuring the COM110A via the datalogger It is possible to reconfigure a GSM modem connected to a logger without the programming ca

Seite 70

CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) F-2 11. The logger should then report “opening 2” (in the case of ComME), which m

Seite 72 -

CAMPBELL SCIENTIFIC COMPANIES Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com  info@campbel

Seite 73

ii 9. Using Loggernet for GPRS communications ... 24 9.1 Setting up to call a logger with a fixed IP address ...

Seite 74

iii E. Resetting the COM110A Module under Program Control ................ E-1 E.1 Princip