INSTRUCTION MANUAL 9522B Iridium Satellite Modem and COM9522B Interface Modem 7/14 Copyright © 2009- 2014 Campbell Scienti

Seite 2

9522B Iridium Satellite Modem and COM9522B Interface Modem TABLE 1-1. Equipment List for Base and Remote Stations Base Station Remote Station 30693

Seite 3 - Limited Warranty

9522B Iridium Satellite Modem and COM9522B Interface Modem TABLE 1-2. Remote Station COM9522B Wiring Hardware ComPort Description Color Connectio

Seite 4 - Assistance

9522B Iridium Satellite Modem and COM9522B Interface Modem FIGURE 1-1. 9522B Base Station Configuration FIGURE 1-2. 9522B Remote Station RS-232 C

Seite 5 - Precautions

9522B Iridium Satellite Modem and COM9522B Interface Modem extra six satellites reserved as backups. This redundancy potentially gives the iridium sy

Seite 6

9522B Iridium Satellite Modem and COM9522B Interface Modem 11 Thornhill Dr., Suite 201 Dartmouth, NS, CANADA, B3B 1R9 T: (902) 405-4428 www.joubeh.co

Seite 7 - Table of Contents

9522B Iridium Satellite Modem and COM9522B Interface Modem 3.2.3 Step 3: DevConfig Communications Once you have clicked Connect, you should be connec

Seite 8 - Figures

9522B Iridium Satellite Modem and COM9522B Interface Modem FIGURE 3-3. CR1000 AT Command String The modem should add a 0 at the end of the command s

Seite 9 - COM9522B Interface Modem

9522B Iridium Satellite Modem and COM9522B Interface Modem To ensure that the settings have been stored in the modem type the command: AT&V. FIG

Seite 10 - 1.3 Hardware Overview

9522B Iridium Satellite Modem and COM9522B Interface Modem This is a summary of the currently active modem profile and ensures that when power is cycl

Seite 11 - 1.4 Power Control

9522B Iridium Satellite Modem and COM9522B Interface Modem FIGURE 4-2. ComPorts Settings Tab 5. LoggerNet Configuration 5.1 Setup of LoggerNet Com

Seite 13 - 2. Specifications

9522B Iridium Satellite Modem and COM9522B Interface Modem 5.1.1 Step 1: LoggerNet Setup Start LoggerNet and open the Setup screen from the Main cate

Seite 14 - 3.2 Setup of Iridium Modems

9522B Iridium Satellite Modem and COM9522B Interface Modem 5.1.2 Step 2: ComPort Configuration With the setup tree entered, you will now need to comp

Seite 15

9522B Iridium Satellite Modem and COM9522B Interface Modem 5.1.3 Step 3: Generic Modem Configuration Select the Generic element as in FIGURE 5-3. En

Seite 16

9522B Iridium Satellite Modem and COM9522B Interface Modem 5.1.4 Step 4: Generic Modem Configuration Continued Click on the Modem tab located next to

Seite 17

9522B Iridium Satellite Modem and COM9522B Interface Modem 5.1.5 Step 5: PakBusPort Configuration As shown in FIGURE 5-5, select the PakBusPort. Be

Seite 18 - 4. Datalogger Configuration

9522B Iridium Satellite Modem and COM9522B Interface Modem 5.1.6 Step 6: CR1000 Configuration Select your datalogger as shown in FIGURE 5-6. Be sure

Seite 19 - 5. LoggerNet Configuration

9522B Iridium Satellite Modem and COM9522B Interface Modem FIGURE 5-7. CR1000 Schedule Configuration 6. Remote Modem Configuration As a matter of s

Seite 20

9522B Iridium Satellite Modem and COM9522B Interface Modem 6.1 Program Example 1 In example 1, the station is a solar powered site where power manage

Seite 21

9522B Iridium Satellite Modem and COM9522B Interface Modem 6.2 Program Example 2 In example 2, the station is a solar powered site where power manage

Seite 22

9522B Iridium Satellite Modem and COM9522B Interface Modem 7. Troubleshooting Tools and Tips Problem: I have intermittent successful connections bet

Seite 23

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Seite 24

9522B Iridium Satellite Modem and COM9522B Interface Modem 22

Seite 25

Appendix A. Sample Data Transfer Calculations The calculations below are based upon maximum theoretical throughputs. Real world transmission times f

Seite 26

Appendix A. Sample Data Transfer Calculations Power Calculation When configuring a power supply (that is, solar panel and battery) for a remote stati

Seite 27 - 6.1 Program Example 1

Appendix B. Hardware Installation The hardware shown in this appendix consists only of hardware listed in TABLE 1-1. Although it may be possible to

Seite 28 - 6.2 Program Example 2

Appendix B. Hardware Installation FIGURE B-3. Installed SIM Card B.2 Antenna Installation These instructions apply to both the base and remote sta

Seite 29

Appendix B. Hardware Installation FIGURE B-4. Antenna, Mount, and Cable Thread the antenna onto the 3/4 inch supplied nut, being sure not to cross

Seite 30

Appendix B. Hardware Installation B.3 9522B Modem Installation The base station installation should be conducted before proceeding to the field to c

Seite 31 - Calculations

Appendix C. Unlocking a SIM Card There are two methods to unlock a SIM card. The equipment you have available will dictate which method is used. C.

Seite 32

Appendix C. Unlocking a SIM Card The next step is to enter the PIN code for the SIM card. AT+CPIN=”1111” <Enter> The modem should respond w

Seite 33 - B.1 SIM Card Installation

Appendix D. Interfacing LoggerNet to RUDICS Contact Campbell Scientific if you are interested in using RUDICS. D.1 Base Station System Requirements

Seite 34 - B.2 Antenna Installation

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Seite 35

Appendix D. Interfacing LoggerNet to RUDICS Serial Port window, select an unused serial port, and add the IP address and port number to connect to.

Seite 36

Appendix D. Interfacing LoggerNet to RUDICS FIGURE D-3. Serial Port Redirector Setup (cont’d) D.4 LoggerNet Setup Now that the serial port emulato

Seite 37 - C.2 DevConfig Method

Appendix D. Interfacing LoggerNet to RUDICS D.4.2 Step 2: Generic Modem Configuration Add a new Generic modem to the ComPort, select a Maximum Baud

Seite 38

Appendix D. Interfacing LoggerNet to RUDICS FIGURE D-6. Generic Modem Configuration (cont’d) Finally, add a PakBusPort and a datalogger and configu

Seite 39 - D.3 Serial Port Redirector

Appendix D. Interfacing LoggerNet to RUDICS D-6

Seite 41 - D.4 LoggerNet Setup

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Seite 42

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Seite 44

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Seite 45

Table of Contents B.2 Antenna Installation ...... B-2 B.3 9522B Modem Installation

Seite 46

9522B Iridium Satellite Modem and COM9522B Interface Modem 1. Overview 1.1 General Description and Modes of Operation The Iridium satellite network

Kommentare zu diesen Handbüchern

Keine Kommentare