Appendix A. Changing GPS16X-HVS
Settings
As configured by Campbell Scientific, the GPS16X-HVS will output the
NMEA 0183 $GPGGA and $GPRMC data strings once a second, the PPS
signal is enabled with a duration of 80 milliseconds and the baud rate is set to
38,400 baud.
Special software (SNRSRCFG.EXE) is available from Garmin International
for system setup. The GPS16X-HVS user manual available from Garmin
International provides technical details beyond the scope of the Campbell
Scientific user manual.
Settings used by Campbell Scientific for GPS16X-HVS setup:
GPS Base Model = GPS 16(X)
Fix Mode = Automatic
Baud Rate = 38,400
Dead Reckon Time = 30 sec
NMEA output time = 1 sec
Position pinning = off
NMEA 2.30 mode = off
Power Save Mode = off (Normal mode)
PPS mode = 1 Hz
PPS Length = 80 mS
Phaze output Data = off
DGPS Mode = WAAS only
Differential mode = Automatic
Earth Datum Index = NGS 84
Selected Sentences = GPGGA and GPRMC
Common changes would be baud rate and selected sentences. The NMEA 0183
GPVTG data sentence gives ground speed and direction, which may be
required for some applications. Changes can be made with the Garmin
software, or with a terminal emulator and the Garmin technical user manual.
Contact Garmin International (www.garmin.com) for either resource.
A.1 Computer Connections
An SC110 cable with sockets is required to connect the GPS16S-HVS to a
computer. The SC110 consists of two cables—each has a 2-foot (0.6 m)
length. Use the cable that has a 9-pin female connector (DCE).
A-1