Page 3
The AM16/32 Multiplexer combines
the functions of our AM416 and AM32
Multiplexers. A toggle switch allows you
to configure the multiplexer to switch 16
sets of 4 lines at a time (4 x 16 mode) or
32 sets of 2 lines at a time (2 x 32 mode).
In either case, a maximum of 64 lines can
be input to the multiplexer. Signals from
the dataloggers control ports trigger
advancement from set to set, sequentially
routing signals from each connected sen-
sor through the multiplexers common
(COM) terminals.
The AM16/32 is smaller and more
robust than its predecessors. In 2 x 32
applications, it uses one less differential
input channel than would be required if
an AM416 were used for the same pur-
pose. Multiple strain relief eyelets are
built into the multiplexer; a cover is also
provided to shield the multiplexer termi-
nal strips and connected wires from inad-
vertent jostling and dust. As with its pre-
decessors, the AM16/32 requires an envi-
ronment free of moisture and condensing
The AM16/32: A smaller, more robust multiplexer
humidity; our AM ENC environmental
enclosure is recommended.
Multiplexers do more than increase
system channel capacity; they can also
significantly reduce the cost of sensor
cabling, especially in applications where
long leads are required. In cases where
sensors are clustered at some distance
from the datalogger, the multiplexer is
typically located in the middle of the sen-
sor spread. The MUXSIGNAL-L and
MUXPOWER-L cables are used for the
long cable run, while expensive sensor
leads are kept short. !!
The AM16/32 can be configured for 32 sets of 2-wire sensors (channel numbers in white), or 16
sets of 4-wire sensors (channel numbers in blue). Select the desired configuration before use by
positioning the switch (white switch surrounded by red square).
Multiplexer Support
in SCWin Version 1.1
The popular SCWin Program
Generator software now has even
more functionalityit supports
Campbell Scientific multiplexers.
SCWin is a software application that
generates a datalogger program for
youno more trying to remember
the right set of program instructions
for each sensor or output option.
You choose the datalogger type,
sensors, and output(s) you want and
SCWin does the rest. With Version
1.1 you can choose the AM416,
AM32, AM25T, or the AM16/32
multiplexer. SCWin will show you a
list of sensor configurations available
for that multiplexer. For conve-
nience, you can add multiple sensors
at the same time. A wiring diagram
is produced and you can even print
out the wiring instructions.
A beta version of SCWin 1.1 is
available at the following address:
www.campbellsci.com/resource.html
If you find problems, want to be
notified of new releases of SCWin,
or have ideas for improvements,
please let us know by email:
CR9052DC updated with FFT spectral analyses
We have added real-time Fast Fourier
Transform spectral analyses to the
CR9000 Measurement and Control
System by updating the code in the
CR9052DC Anti-Alias Filter Module.
The high-performance DSP in the
CR9052 rivals the speed and capabilities
of PC-based systems. In addition, the
CR9000 system offers a rugged, portable,
12 Vdc powered solution. The CR9052
can perform 2048-point FFTs on six
channels in real-time.
The normal processing sequence is
to collect a snapshot of time-series
data, apply a time-series window
(optional), perform the FFT, nor-
malize the results into spectra
(amplitude and phase, power,
power spectral density, and dB
are options). In addition, the
CR9052 can combine adjacent
spectral components to provide
1/n octave analyses. !!
CR9052DC featured in international publication
The November edition of Testing
Technology International, a U.K.-based
periodical specializing in measure-
ments germane to vehicle testing, fea-
tured an article about our CR9052DC
anti-alias filter card for the CR9000
Measurement and Control System. The
article explains the exceptional capabil-
ities provided by the CR9052 for anti-
alias rejection on analog voltage mea-
surements and the CR9052s ability to
perform near real-time Fast Fourier
Transform analyses. A PDF version of
the article appears on our Web site. !
The CR9052DC’s (right) anti-alias and FFT capabilities add
functionality to the CR9000 Measurement & Control System.
Speed rivals PC-based systems
Seitenansicht 2
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare