Campbell Met One 034A-L Bedienerhandbuch Seite 15

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 14
Met One 034B Wind Set
8. If LoggerNet, PC400, RTDAQ, or PC200W is running on your PC,
and the PC to datalogger connection is active, you can click Finish in
Short Cut and you will be prompted to send the program just created
to the datalogger.
9. If the sensor is connected to the datalogger, as shown in the wiring
diagram in step 6, check the output of the sensor in the datalogger
support software data display to make sure it is making reasonable
measurements.
5. Overview
The 034B, Wind Set is used to measure horizontal wind speed and direction.
Wind speed is measured with a three cup anemometer. Rotation of the cup
wheel opens and closes a reed switch at a rate proportional to wind speed.
Vane position is transmitted by a 10 kΩ potentiometer. With a precision
excitation voltage applied, the output voltage is proportional to wind direction.
The accompanying Met One manual contains additional information on the
operating principals, installation, and maintenance of the sensor. The Met One
manual is also available at their website (www.metone.com).
Cable length for the 034B is specified when the sensor is ordered. TABLE 5-1
gives the recommended cable length for mounting the sensor at the top of the
tripod/tower with a CM202 crossarm.
TABLE 5-1. Recommended Cable Lengths
CM106 CM110 CM115 CM120 UT10 UT20 UT30
11 ft 14 ft 19 ft 24 ft 14 ft 24 ft 37 ft
The 034B’s cable can terminate in:
Pigtails that connect directly to a Campbell Scientific datalogger
(option PT).
Connector that attaches to a prewired enclosure (option PW). Refer
to www.campbellsci.com/prewired-enclosures for more information.
Connector that attaches to a CWS900, Wireless Sensor Interface
(option CWS). The CWS900 allows the 034B to be used in a
wireless sensor network. Refer to www.campbellsci.com/cws900 for
more information.
6. Specifications
Features:
Designed for continuous, long term, unattended operation in adverse
conditions
Constructed of light-weight aluminum
Compatible with Campbell Scientific CRBasic dataloggers: CR6,
CR200(X) series, CR800 series, CR1000, CR3000, CR5000, and
CR9000X
7