
Model HFP01SC Self-Calibrating Soil Heat Flux Plate
19: Z=X-Y (P35)
1: 9 X Loc [ work ]
2: 5 Y Loc [ mV_180 ]
3: 9 Z Loc [ work ]
20: Z=ABS(X) (P43)
1: 9 X Loc [ work ]
2: 9 Z Loc [ work ]
21: Z=X/Y (P38)
1: 3 X Loc [ cal ]
2: 9 Y Loc [ work ]
3: 3 Z Loc [ cal ]
22: End (P95)
23: End (P95)
End Program
-Input Locations-
1 shf
2 shf_mV
3 cal
4 mV_0
5 mV_180
6 mV_end
7 V_Rf
8 shf_mV_a
9 work
TABLE 4. Wiring for Example 2
Description Color CR23X
Sensor Signal White 9H
Sensor Signal Reference Green 9L
Shield Clear
Heater Resistor Signal Yellow 10H
Heater Resistor Signal Reference Purple 10L
Shield Clear
Power Red SW12
Power Reference Black G
9
Kommentare zu diesen Handbüchern