Campbell cs215 Bedienungsanleitung Seite 15

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 56
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 14
MetPak Doc No 1575-PS-0001 Issue 02 CN 4240 March 2006
TB3 TB1
Connections from WindSonic
Connections from Rotronic
Temperature and Relative Humidity
Senso
r
Outputs to Customer Equipment
TB2 TB4
Connecting to an SDI-12 Interface (Option 1 and 2)
TB 3 Junction Box
10 Way Terminal Block
Data logger or
Chart recorder
Signal names Signal names
Signal GND
V-
V+
TXD-
RXD-
3
10
9
1
2
GND
+V (9-16Vdc)
Serial Data Line
Note: SW1 must be in closed position for SDI-12 option. If you wish to use RS232 programming port then SW1 must be
in open position and only external links between TXD- and RXD- must be temporarily removed.
TB1 TB3
Connections from WindSonic
Connections from Campbell
SDI12 Temperature and
Relative Humidity Sensor
Ouputs to Customer
Equipment
TB2 TB4
14
Seitenansicht 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 55 56

Kommentare zu diesen Handbüchern

Keine Kommentare