AD-9-1
SECTION 9. INPUT/OUTPUT INSTRUCTIONS
*** 18 MOVE TIME TO INPUT LOCATION ****
FUNCTION
This instruction takes current time or date
inf
ormation and does a modulo divide (see
Instruction 46) on the time/date value with the
number specified in the second parameter. The
result is stored in the specified Input Location.
Entering 0 or a number greater than the
m
aximum value of the time/date for the modulo
divide will result in the actual time/date value
being stored.
PARAMETER 1 CODES
Code Time/Date Units
00 Seconds into day (maximum 86400)
01 Minutes into day (maximum 1440)
02 Hours into year (maximum 8784)
03 Hours into day (maximum 24)
04 Day of month (maximum 31)
05 Month of year (maximum 12)
06 YR MO DAY HR MIN SEC
PARAM DATA
NUMBER TYPE DESCRIPTION
01: 2 Time/Date Code
02: 4 Number to modulo
divide by
03: 4 Input Location Number
Input Locations altered: 1