Campbell CR200 Bedienungsanleitung Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
3
* e factory default settings for the logger may not match the settings for the RF401-series radio; therefore, the logger and radio must be recon-
gured before communications can take place.  e "Quick Reference Guide for Setting Up RF401-to-CR206 Communications" application note
provides more information (see www.campbellsci.com/app-notes).
Models/Communications
All of the models can communicate with a PC via direct
connect, NL100 Ethernet Interface, MD485 multidrop
modem, and our digital cellular modems. Data can also
be viewed on the CD295 DataView II display or a PDA
(PConnect or PConnectCE so ware required).
Other communications supported are model dependent:
CR200—base model (i.e, only supports direct
connect, Ethernet, digital cellular modems,
MD485 multidrop modems, CD295 DataView
displays, and PDAs).
CR206 —includes an internal 915 MHz spread
spectrum radio that transmits data to another
CR206 datalogger or an RF401 radio*.  e
915 MHz frequency is used in the US/Canada.
CR211 —includes an internal 922 MHz spread
spectrum radio that transmits data to another
CR211 datalogger or an RF411 radio*.  e
922 MHz frequency is used in Australia/Israel.
CR216 —includes an internal 2.4 GHz spread
spectrum radio that transmits data to another
CR216 datalogger or an RF416 radio*.  e 2.4 GHz
frequency can be used in many countries worldwide.
CR295 —includes an additional 9-pin serial port
and an instruction set that allows communications
with the TX312 HDR GOES satellite transmitter.
e CR295 does not support radio telemetry and
calculation of evapotranspiration.
Program Development Tools
e programming language of the CR200-series
dataloggers is CRBasic. Datalogger programs are
developed using a program editor (programs cannot
be created or edited in the datalogger). Program edi-
tors that can be used with these dataloggers include
the CRBasic editor and Short Cut.  e CRBasic editor
is included in our PC400 and LoggerNet Datalogger
Support So ware. Short Cut can be obtained, at no
charge, from: www.campbellsci.com/downloads
Communication & Data Collection Tools
PC200W
PC200W, our starter communications so ware, sup-
ports direct communications between a PC and a
CR200-series datalogger and provides numeric display
of measurements PC200W can be obtained, at no
charge, from: www.campbellsci.com/downloads
PC400
PC400 Datalogger Support Software supports
programming, manual data collection, and data
display. Both direct and telemetry communications
are supported.
LoggerNet 2.1 or higher
Besides providing all of PC400’s functions, LoggerNet
Datalogger Support So ware supports automatic data
collection and PB® routing.
Short Cut is available from our website (at no charge) and
Resource CD. It is also bundled with PC200W, PC400, and
LoggerNet Software.
The CR295 and our TX312 transmitter
are used for stream stage (shown), water
quality, and rainfall applications.
Seitenansicht 2
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare