Supported switching arrangements:
Relay
Control
Microcontroller
12V
GROUND
RESET
CLOCK
COM HI 1
COM LO 1
CR800/CR1000
Sensor #1
12V
GROUND
RESET
CLOCK
Multiplexer/Terminal Board
AG
Sensor
Shield
COM HI 2
COM LO 2
Sensor #16
Sensor
Shield
1H
2H
1L
2L
S1
31H
32H
31L
32L
S16
Figure 1 - 16 Channel Switching Block Diagram
The 16 channel 4 wire switching configuration is typically used to multiplex 4 wire
sensors such as resistance strain gage load cells. It is also used to switch connections for
instruments which have more than one sensor integral to them, such as vibrating wire
pressure transducers with an integral thermistor for measuring temperature.