AM25T Solid State Multiplexer
13
Example 3. 21X Program for Measuring 25 Type T Thermocouples or Voltage Sensors Using
a Differential Instruction
*Table 1 Program
01: 10 Execution Interval (seconds)
01: Do (P86) ;Turn On AM25T
1: 42 Set Port 2 High
02: Full Bridge (P6) ;Measure the output of the reference temp. full bridge
1: 1 Reps
2: 3 50 mV Slow Range ;See Table 6-1 for older AM25T multiplexers
3: 1DIFF Channel
4: 1 Excite all reps w/Exchan 1
5: 2400 mV Excitation ;See Table 6-1 for older AM25T multiplexers
6: 1 Loc [ RefTemp_C ]
7: -0.001 Mult
8: 0.09707 Offset
03: BR Transform Rf[X/(1-X)] (P59) ;Calculate RTD resistance R/R0
1: 1 Reps
2: 1 Loc [ RefTemp_C ]
3: 10.025 Multiplier (Rf)
04: Temperature RTD (P16) ;Calculate reference temperature
1: 1 Reps
2: 1 R/R0 Loc [ RefTemp_C ]
3: 1 Loc [ RefTemp_C ]
4: 1 Mult
5: 0 Offset
05: Beginning of Loop (P87) ;Loop through thermocouple channels
1: 0 Delay
2: 25 Loop Count
06: Do (P86) ;Clock the AM25T twice
1: 41 Set Port 1 High ;Setting high then low is faster than pulsing w/21X
07: Do (P86)
1: 51 Set Port 1 Low
08: Do (P86)
1: 41 Set Port 1 High
09: Do (P86)
1: 51 Set Port 1 Low