TX312 Transmitter
; Write a time stamp to final storage
2: Real Time (P77)
1: 1221 Year,Day,Hour/Minute,Seconds (midnight = 2400)
; Write 41 input locations to final storage
3: Sample (P70)
1: 41 Reps
2: 1 Loc [ Status_RC ]
; Check if top of 4 hour interval, if true execute P126
4: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 240 Interval (same units as above)
3: 30 Then Do
; Transfer data to TX312
5: Data Transfer to HDR GOES (P126)
1: 0 Self-Timed/Append
2: 0 Binary Format
3: 41 Result Code Loc [ P126_RC ]
6: End (P95)
; Check result code for P126, if between 1 and 6 P126 will be executed again.
7: If (X<=>F) (P89)
1: 41 X Loc [ P126_RC ]
2: 3 >=
3: 1 F
4: 30 Then Do
8: If (X<=>F) (P89)
1: 41 X Loc [ P126_RC ]
2: 4 <
3: 7 F
4: 30 Then Do
; Increment counter to count number of time P126 has been tried again
9: Z=Z+1 (P32)
1: 42 Z Loc [ Counter ]
; Try P126 again
10: Data Transfer to HDR GOES (P126)
1: 0 Self-Timed/Append
2: 0 Binary Format
3: 41 Result Code Loc [ P126_RC ]